Skip to main content
. 2021 Feb 26;26(1):25–35. doi: 10.1007/s00779-021-01541-4

Table 2.

X-Ray image classification result using RNN and CNN for COVID-19 detection

Threshold True positive (COVID-19) False positive (non-COVID-19) True negative (COVID-19) False negative (non-COVID-19) Total number of tested images Sensitivity (%) Specificity (%) Accuracy (%)
0.5 65 41 1115 85 1306 43.33 96.45 90.35
0.6 70 36 1124 76 47.94 96.89 91.42
0.7 75 31 1135 65 53.57 97.34 92.64
0.8 79 27 1148 52 60.30 97.70 93.95
0.9 85 21 1160 40 68.00 98.22 95.32
1 96 10 1180 20 82.75 99.15 97.70