Skip to main content
. 2021 Feb 24;5(3):e543. doi: 10.1097/HS9.0000000000000543

Table 1.

Overall Comparison of ddPCR Versus RQ-PCR MRD Results by All IG/TR Markers (1.5 μg DNA Was Used in Both).

ddPCR
RQ-PCR POS-Q (%) POS-NQ (%) NEG (%) Total (%)
POS-NQ 21 (20) 25 (23.8) 59 (56.2) 105 (100)
NEG 5 (1.7) 34 (11.6) 253 (86.7) 292 (100)
Total 26 (6.5) 59 (14.9) 312 (78.6) 397 (100)

Concordant values between ddPCR and RQ-PCR are indicated in bold.

ddPCR = droplet digital polymerase chain reaction; IG = immunoglobulin; MRD = minimal residual disease; NEG = negative; POS-NQ = positive not-quantifiable; POS-Q = positive quantifiable; RQ-PCR = real-time quantitative polymerase chain reaction; TR = T-cell receptor.