Comparison between different bolometer detectors.

Parameter [30] [32] Conventional [31] Meshed Leg [31] Extended Leg [31] [33] [37] [44]
Material Vanadium Oxide Amorphous-Si Amorphous-Si Amorphous-Si Amorphous-Si Aluminum (CMOS) ZnO Cytochrome C
N of thermocouples 80 320 160 96 NA 32 6 184
Responsivity [V/W] NA 10 × 104 NA NA NA 1.751 × 103 NA 1.5 × 105
TCR [%/K] −2.7 NA NA NA NA 0.385 −10.5 29
Time Constant [ms] NA NA 10.68 16.66 4.39 5.27 0.24 NA
Gth [W/K] NA NA 3.7 × 10−8 2.4 × 10−8 9.1 × 10−8 1.41 × 10−6 NA NA