Table 4.
Energy consumption comparison of RO membrane operating conditions with NF and UF membranes.
RO | NF | UF | ||||
---|---|---|---|---|---|---|
30 L·m−2 h−1 Flux | 25 L·m−2 h−1 Flux | 30 L·m−2 h−1 Flux | ||||
% Recovery (ϒ) | 75% Recovery (ϒ) | |||||
Parameter | 75 | 50 | 75 | 50 | ||
∆P (kPa) | 384.2 | 423.7 | 385.7 | 389.2 | 298.7 | 269.7 |
QB (m3·h−1) | 0.081 | 0.243 | 0.068 | 0.204 | 0.063 | 0.205 |
QP (m3·h−1) | 0.243 | 0.243 | 0.2024 | 0.204 | 0.19 | 0.205 |
QF (m3·h−1) | 0.324 | 0.486 | 0.270 | 0.405 | 0.253 | 0.41 |
SEC (kWh·m−3) | 0.142 | 0.235 | 0.143 | 0.216 | 0.111 | 0.100 |