Skip to main content
. 2021 Feb 6;11(2):117. doi: 10.3390/membranes11020117

Table 4.

Energy consumption comparison of RO membrane operating conditions with NF and UF membranes.

RO NF UF
30 L·m−2 h−1 Flux 25 L·m−2 h−1 Flux 30 L·m−2 h−1 Flux
% Recovery (ϒ) 75% Recovery (ϒ)
Parameter 75 50 75 50
∆P (kPa) 384.2 423.7 385.7 389.2 298.7 269.7
QB (m3·h−1) 0.081 0.243 0.068 0.204 0.063 0.205
QP (m3·h−1) 0.243 0.243 0.2024 0.204 0.19 0.205
QF (m3·h−1) 0.324 0.486 0.270 0.405 0.253 0.41
SEC (kWh·m−3) 0.142 0.235 0.143 0.216 0.111 0.100