Skip to main content
. 2021 Feb 13;21(4):1338. doi: 10.3390/s21041338

Table 4.

Sensitivity (true-positive rate, TPR), specificity (true-negative rate, TNR), and accuracy (ACC) for the faller classification using the SWAP 4 and SWAP 82 tasks.

Neurons Epochs Regularisation SWAP 4 SWAP 82
TPR TNR ACC TPR TNR ACC
5 2 false 88% 75% 85% 94% 38% 83%
5 2 true 91% 25% 78% 88% 50% 80%
5 4 false 84% 38% 75% 84% 50% 78%
5 4 true 97% 0% 78% 81% 50% 75%
5 20 false 75% 38% 68% 88% 75% 85%
5 20 true 94% 13% 78% 81% 75% 80%
7 2 false 69% 38% 63% 91% 75% 88%
7 2 true 88% 25% 75% 78% 50% 73%
7 4 false 88% 13% 73% 82% 88% 83%
7 4 true 88% 0% 70% 88% 50% 80%
7 20 false 78% 38% 70% 91% 88% 90%
7 20 true 94% 0% 75% 88% 88% 88%
10 2 false 66% 63% 65% 88% 50% 80%
10 2 true 82% 25% 70% 78% 63% 75%
10 4 false 88% 25% 75% 88% 88% 88%
10 4 true 84% 13% 70% 81% 25% 70%
10 20 false 75% 25% 65% 84% 88% 85%
10 20 true 91% 13% 75% 81% 50% 75%