Skip to main content
. 2018 Jun 14;5:51. doi: 10.3389/frobt.2018.00051

Figure 8.

Figure 8

Valve current loop responses (solid red lines) for a current step input (dashed blue lines) of 4 mA: (A) open-loop current response and (B) closed-loop current response considering a proportional controller with Kp = 4.55 V/mA. The static gain Ksg extracted from (A) has approximated value of 0.4.