Direct polymer bonding results. (*) low optical quality; (**) Good results only on one side of the membrane, unable to obtain a proper polymer-PC membrane-polymer sandwich; (-) not tested.

1st Material COP PS PMMA PC
2nd Material COP PC APTES—PC PS PC APTES—PC PMMA PC PC
Low Power O2 Plasma 1 min None None None - - - None None None
2 min None None Good ** None - None None None None
10 min None Poor Good ** None None None None None None
Method 5 min None None None None None None None None None
UVO3 10 min Poor None Poor None - - None None None
20 min Good None Poor None None None None None None
Solvent Good * None - Good * None - Good * None Poor