Skip to main content
. Author manuscript; available in PMC: 2022 Feb 2.
Published in final edited form as: IEEE Trans Med Imaging. 2021 Feb 2;40(2):635–647. doi: 10.1109/TMI.2020.3034038

TABLE I.

Quantitative evaluation of FiberCup tests with Tractometer protocol [24]. Best results are in bold. All techniques found all 7 valid bundles (VB). First column shows the number of invalid bundles (IB). Other columns show values of no (NC), invalid (IC), valid (VC) connection ratios and the Overall score. For all algorithms, best Overall scoring result were listed. According to this, for MRtrix algorithms, step sizes were 0.6 mm, 0.45 mm, 1.125 mm, 0.15 mm and angles were 60°, 30°, 30°, 30° for SD_STREAM, iFOD1, iFOD1 (-rk4) and iFOD2 algorithms respectively. For the proposed algorithm, step size, probe length and radius were 0.03 mm, 1 mm and 1.5 mm respectively. For all algorithms, FOD amplitude constraint (fmin for the proposed approach) was 0.0075.

IB(#) NC(%) IC(%) VC(%) Overall
SD_STREAM 10 80.4 1 18.6 1.14
iFOD1 23 73.4 7.7 19 1.1
iFOD1 (-rk4) 18 71 4.3 24.7 1.04
iFOD2 21 77.8 7.5 14.7 1.16
Proposed 17 65.6 4.9 29.4 0.96