Table 5.

Breakdown of estimated basal EUI for each typology from energy audits.

Typology Building Area (m²) End use Units Power installed (W) Break-down of power installed Motivation (reason for end use) Average Estimated Monthly Energy Consumption (kWh) Break-down of remained con-sumption Whole-building EUI estimated by TM22 (kWh/m²/month)
Administrative Building SMDU 5,864.91 Lighting systems for security (external areas, corridors, etc.) 68 1,020 1 % Security reasons 520 5% 1.77
(actual 2.22)
Data processing centers 10 30,000 40% Server for municipal sites 7,650 74%
Computers in stand-by mode 289* 43,350 58% Inefficiency and/or work-from-home needs 2,211 21 %
Elementary School EEB Beatriz de Souza Brito 2,183.44 Lighting system for security (external area, corridors, etc.) 147 8,708 86 % Security reasons 639 48 % 0.61
(actual 0.66)
Refrigerators 5 423 4% Maintain operation (even when empty) 190 14%
Computers in stand-by mode 37 975 10 % Inefficiency 510 38 %
Nursery School NEIM Costeira do Pirajubaé 446.77 Lighting system for security (external areas, corridors, etc.) 17 2,200 81 % Security reasons 110 22 % 1.12
(actual 1.70)
Refrigerators 5 310 11 % Maintain operating (even when empty) 226 45%
Computers in stand-by mode 4 212 8% Inefficiency 163 33 %
*

Total number of computers in the building considered in stand-by mode.