TABLE 1.
Test items | Transparent cellulose film (90°C, 3 h) | Translucent cellulose film (80°C, 4 h) | Polyethylene film (Yaptenco et al., 2007) |
Thickness, μm | 21.1 ± 2.4 A# | 23.1 ± 0.5 A | 25.1 ± 0.6 |
Tensile strength, MPa | 32.8 ± 7.2 A | 77.0 ± 2.5 B | N/A |
Extension at break, % | 4.0 ± 0.5 A | 3.1 ± 0.4 A | N/A |
Water vapor transmission rate, g/(m2⋅24 h) | 1,969.1 ± 88.5 A | 1,765.9 ± 23.4 A | N/A |
Gas permeability rate, g/(m2⋅24 h) | 10,015.4 ± 1,117.1 A | 9,325.8 ± 526.9 A | 5,703.9–8,526.1 |
#Values are expressed as mean ± SEM (n = 3). Values in the same row followed by the same uppercase letter are not significantly different at P = 0.05, according to Duncan’s multiple range test.