Table 2.
PI-QUAL score | Criteria | Clinical Implications |
---|---|---|
1 | All mpMRI sequences are below the minimum standard for diagnostic quality | It is NOT possible to rule in all significant lesions a
It is NOT possible to rule out all significant lesions a |
2 | Only one mpMRI sequence is of acceptable diagnostic quality | |
3 |
At least two mpMRI sequences taken together are of acceptable diagnostic quality |
It is possible to rule in all significant lesions It is NOT possible to rule out all significant lesions |
4 | Two or more mpMRI sequences are independently of optimal diagnostic quality | It is possible to rule in all significant lesions It is possible to rule out all significant lesions |
5 | All mpMRI sequences are of optimal diagnostic quality |
PI-QUAL, Prostate Imaging Quality; PI-RADS, Prostate Imaging Reporting and Data System; mpMRI, multiparametric magnetic resonance imaging.
Reprinted from Giganti F, Allen C, Emberton M, Moore CM, Kasivisvanathan V, for the PRECISION study group. Prostate Imaging Quality (PI-QUAL): A New Quality Control Scoring System for Multiparametric Magnetic Resonance Imaging of the prostate from the PRECISION trial. Eur Urol Oncol; 3(5):615-619. doi: 10.1016/j.euo.2020.06.007. Copyright (2020), with permission from Elsevier (https://euoncology.europeanurology.com).
Therefore reports should not include PI-RADS or Likert scores.