Skip to main content
. 2020 Dec 2;94(1118):20201046. doi: 10.1259/bjr.20201046

Table 4.

Sensitivity, specificity, PPV, NPV and accuracy of MG, DBT, ultrasound and CEDM

Imaging modalities Sensitivity Specificity PPV NPV Accuracy
MG (s2D) 75.6% 63.3% 69.1% 70.4% 69.7%
DBT (3D) 82.8% 84.8% 85.7% 81.7% 83.7%
Ultrasound + DBT 88.5% 79.7% 82.8% 86.3% 84.3%
CEDM 96.5% 81% 84.8% 95.5% 89.2%
p-value:
 CEDM vs .MG <0.0001 0.0002 0.0007 <0.0001 <0.0001
 CEDM vs DBT <0.0001 0.3586 0.8174 0.0001 0.1438
 CEDM vs ultrasound + DBT 0.0057 0.4135 0.6215 0.0036 0.1886
 DBT vs MG 0.1066 <0.0001 0.0003 0.0160 0.0026
 DBT vs ultrasound + DBT 0.1399 0.2654 0.4689 0.2537 0.8816
 Ultrasound + DBT vs. MG 0.0022 0.0007 0.0159 0.0004 0.0016

CEDM, contrast-enhanced digital mammography; DBT, digital breast tomosynthesis; MG, mammography; NPV, negative predictive value; PPV, positive predictive value.