Skip to main content
. 2021 Mar 5;292:114121. doi: 10.1016/j.jviromet.2021.114121

Table 1.

Statistical agreements between three automated platforms for SARS-CoV-2 antibodies. Value of ĸ <0.20 poor agreement, 0.21-0.40 fair agreement, 0.41-0.60 moderate agreement, 0.61-0.80 good agreement, and 0.81-1.00 very good agreement. p-value <0.001 was statistically very significant.

Roche vs Abbott Abbott
Total
Positive Negative
Roche Positive 380 (54.8 %) 98 (14.1 %) 478 (68.9 %)
Negative 4 (0.6 %) 212 (30.5 %) 216 (31.1 %)
Total 384 (55.3 %) 310 (44.7 %) 694 (100 %)
Kappa Value 0.694 (0.641−0.746)
McNemar’s Test p-value <0.001
Total Agreement 85.3 %
Positive Agreement 79.4 %
Negative Agreement 98.1 %
Yhlo vs Abbott Abbott
Total
Positive Negative
Yhlo Positive 380 (54.8 %) 77 (11.1 %) 457 (65.9 %)
Negative 4 (0.6 %) 233 (33.6 %) 237 (34.1 %)
Total 384 (55.3 %) 310 (44.7 %) 694 (100 %)
Kappa Value 0.758 (0.709−0.807)
McNemar’s Test p-value <0.001
Total Agreement 88.3 %
Positive Agreement 83.1 %
Negative Agreement 98.3 %
Roche vs Yhlo Yhlo
Total
Positive Negative
Roche Positive 451 (65.0%)27 (3.9%)478 (68.9 %) 27 (3.9 %) 478 (68.9 %)
Negative 6 (0.9 %) 210 (30.3 %) 216 (31.1 %)
Total 457 (65.9 %) 237 (34.1 %) 694 (100 %)
Kappa Value 0.892 (0.856−0.927)
McNemar’s Test p-value <0.001
Total Agreement 95.2 %
Positive Agreement 94.3 %
Negative Agreement 97.2 %