Skip to main content
. 2021 Mar 5;9:23. doi: 10.1186/s40560-021-00538-8

Table 3.

Discrimination ability of the model in the test dataset using a 50% probability-of-intubation cut-off

Parameter Value (95% CI)
Sensitivity 83% (68-91%)
Specificity 89% (74-95%)
Positive predictive value 89% (76-96%)
Negative predictive value 82% (67-91%)
Positive likelihood ratio 7.3 (2.9-18.4)
Negative likelihood ratio 0.20 (0.09-0.38)

CI confidence interval