Table 4.
Results of simulations
| Result | CFPP | CFPP + PCC + SSWC | CFPP + PCC + CC-4 | CFPP + PCC + CC-6 | CFPP + PCC + CC-8 |
|---|---|---|---|---|---|
| Stripper reboiler duty (MW) | – | 431.94 | 431.94 | 431.94 | 431.94 |
| Power consumed by compressors (MW) | – | 46.12 | 42.18 | 38.45 | 37.12 |
| Net power output (MWe) | 550 | 365.26 | 369.2 | 372.93 | 374.26 |
| CO2 captured (kg/s) | 110.3 | 110.3 | 110.3 | 110.3 | 110.3 |
| GWP (e-CO2 g/kWh) | 802.15 | 129.07 | 127.7 | 126.42 | 125.97 |
| CFPP efficiency (HHV) | 39.3% | 26.1% | 26.38% | 26.64% | 26.74% |