Table 5.
Results of thermal integration
| Result | CFPP | CFPP + PCC + SSWC | CFPP + PCC + CC-4 | CFPP + PCC + CC-6 | CFPP + PCC + CC-8 |
|---|---|---|---|---|---|
| Stripper reboiler duty (MW) | – | 390.4 | 412.53 | 431.58 | 431.94 |
| LP steam extracted (kg/s) | – | 162.1 | 171.3 | 179.21 | 179.36 |
| Power consumed by the compressors (MW) | – | 46.12 | 42.18 | 38.45 | 37.12 |
| ORC power output (MWe) | – | 5.8 | 7.9 | 7.91 | 4.67 |
| Net power output (MWe) | 550 | 382.9 | 382.64 | 380.9 | 379.61 |
| CO2 captured (kg/s) | 110.3 | 110.3 | 110.3 | 110.3 | 110.3 |
| GWP (e-CO2 g/kWh) | 802.15 | 123.12 | 123.21 | 123.35 | 124.42 |
| CFPP efficiency (HHV) | 39.3% | 27.4% | 27.34% | 27.22% | 27.12% |