Table 1. Data collection and processing.

Values in parentheses are for the highest resolution shell.

Diffraction source Beamline 24-ID-E, APS
Wavelength (Å) 0.97918
Temperature (K) 100
Detector ADSC Quantum 315 CCD
Crystal-to-detector distance (mm) 300
Rotation range per image (°) 0.75
Total rotation range (°) 90
Exposure time per image (s) 1
Space group P212121
a, b, c (Å) 58.39, 81.61, 106.81
Mosaicity (°) 0.317
Resolution range (Å) 50.00–2.15 (2.19–2.15)
Total no. of reflections 260436
No. of unique reflections 28521 (1406)
Completeness (%) 99.5 (99.9)
Multiplicity 3.60 (3.50)
I/σ(I)〉 10.46 (2.05)
R r.i.m. 0.155 (0.864)
Overall B factor from Wilson plot (Å2) 30.46

Estimated R r.i.m. = R merge[N/(N − 1)]1/2, where N is the data multiplicity.