Table 2. Parameters of the beamline mirrors.

M1/M2 is the hard X-ray KB mirror pair, M3/M4 the soft X-ray mirror pair for the first endstation, and M5/M6 the mirror pair for the second endstation. Object distances are measured from the undulator source (M1, M2, M3 and M5) and the exit slit of the PGM (M4 and M6), respectively. For M1 and M2, image distances for both endstations are given.

  M1 M2 M3 M4 M5 M6
Distance to source (mm) 23945 26485 30653 31105 32735 33187
Final shape Cylindrical Cylindrical Elliptical Elliptical Elliptical Elliptical
Object distance (mm) 23945 26485 30653 5605 32735 7687
Image distance (mm) 8055/10555 5515/8015 1347 895 1765 1313
Optically active area (mm2) 1300 × 40 400 × 40 400 × 30 200 × 30 400 × 30 200 × 30
Angle of incidence (°) 0.25 0.25 1.5 1.5 1.5 1.5
Coating Si and Rh Si and Rh Ni and Rh Ni and Rh Ni and Rh Ni and Rh
Substrate material Si Si Si Si Si Si