Table 2.

Specificity comparison of five brands of COVID-19 RDTs against dengue-confirmed samples

Specificity (%, 95% CI)
IgG IgM
Cellex 100% (95% CI 92.5–100) 98.3% (95% CI 89.9–99.9)
Dynamiker 100% (95% CI 92.5–100) 100% (95% CI 92.5–100)
Genbody 100% (95% CI 92.5–100) 100% (95% CI 92.5–100)
Standard diagnostics 98.3% (95% CI 89.9–99.9) 98.3% (95% CI 89.9–99.9)
VivaChek 100% (95% CI 92.5–100) 100% (95% CI 92.5–100)
p-value 0.404 0.555