Overview of the affected total body surface of the nine patients. Outcome after initial grafting need for secondary procedures and woundhealing in the postoperative course after initial reconstruction with Matriderm® and STSG. Woundhealing was judged as completed when the STSG or the flap in patient 3 was clinically stable and allowed at the beginning of physioterapy

Patient Age Mechanism Outcome Secondary Procedures Woundhealing completed
1 34 38% high‐voltage distribution box Successful grafting Not needed 9 days p.o.
2 19 46% contact to train power line Successful grafting Not needed 10 days p.o.
3 27 91% contact to train power line Secondary free flap Free flap 26 days p.o.
4 54 84% high‐voltage distribution box Successful grafting Not needed 9 days p.o.
5 44 82% contact to power line Successful regrafting 1 × Regrafting 18 days p.o.
6 35 16% high‐voltage distribution box Successful grafting Not needed 9 days p.o.
7 29 27% high‐voltage current Successful grafting Not needed 10 days p.o.
8 42 48% high‐voltage current Successful regrafting 1 × Regrafting 19 days p.o.
9 48 64% contact to train power line Successful grafting Not needed 10 days p.o.