Skip to main content
. 2009 Oct 7;6(Suppl 2):1–25. doi: 10.1111/j.1742-481X.2009.00628.x

Table 3.

NPWT/ROCF systems: contraindications, warnings and precautions recommended by the panel *

CONTRAINDICATIONS WARNINGS PRECAUTIONS
Gross infection If bleeding develops, discontinue therapy Exposed blood vessels, nerves or organs must be protected using overlying fascia, tissue, or other protective barrier
Sepsis Protect vessels and organs (cover with thick layers of natural tissue or meshed non‐adherent material) Extreme care must be taken in the presence of existing or potential bleeding problems
Recurrent deep wound infection Use therapy cautiously in presence of infected blood vessels Bone fragments or sharp edges that could puncture protective barriers, vessels, or organs should be managed by debriding sharp edges
Presence of a pseudoaneurysm Smooth and cover any residual sharp edges to decrease risk of serious or fatal injury Extreme care must be taken to protect vascular anastomoses, including coronary artery bypass grafts, or weakened, irradiated, or sutured blood vessels or organs
Malignancy Monitor hemostasis, anticoagulants, and platelet aggregation inhibitors
Lack of local wound hemostasis Monitor infected wounds closely; may require more frequent dressing changes than non‐infected wounds
Untreated osteomyelitis NPWT/ROCF‐silver is not intended to replace use of systemic therapy
Unprotected vascular anastomoses
Foam placement directly over weakened or irradiated vessels
*

This table does not necessarily reflect the contraindications, warnings, and precautions provided in the manufacturer's labeling.