Fault index Type Time delay Number of samples Description
Fault1 Step None 600 A/C feed ratio, B composition constant
Fault2 Step None 600 B composition, A/C ratio constant
Fault3 Step None 600 D feed temperature
Fault4 Step 40 minutes 600 Reactor cooling water inlet temperature
Fault5 Step 40 minutes 600 Condenser cooling water inlet temperature
Fault6 Step 40 minutes 600 A feed loss
Fault7 Step 40 minutes 700 C header pressure loss-reduced availability
Fault8 Random 40 minutes 600 A, B, C feed composition
Fault9 Random 40 minutes 600 D feed temperature
Fault10 Random None 600 C feed temperature
Fault11 Random None 600 Reactor cooling water inlet temperature
Fault12 Random 50 700 Condenser cooling water inlet temperature
Fault13 Slow drift None 600 Reaction kinetics
Fault14 Sticking 40 minutes 600 Reactor cooling water valve
Fault15 Sticking None 600 Condenser cooling water valve
Fault16 Unknown 40 minutes 700 Unknown
Fault17 Unknown 40 minutes 600 Unknown
Fault18 Unknown None 600 Unknown
Fault19 Unknown None 600 Unknown
Fault20 Unknown None 600 Unknown
Normal 17700 A/C feed ratio, B composition constant