Skip to main content
. 2016 Jan;37(1):28–36. doi: 10.3174/ajnr.A4474

Sensitivity, specificity, and cutoff values of best models for classificationa

Model Sensitivity Specificity Cutoff Values AUC 95% CI
TP vs PsP + mixed
    CP 0.71 0.90 0.07 0.84 0.72–0.96
    FA 0.71 0.75 0.13 0.78 0.64–0.93
    CL 0.71 0.75 0.04 0.72 0.56–0.88
    rCBVmax 0.62 0.80 4.06 0.77 0.63–0.92
    FA + CL + rCBVmax 0.76 0.95 0.55 0.90 0.81–1.00
PsP vs TP + mixed
    CP 0.57 1.00 0.07 0.74 0.59–0.89
    FA 0.40 1.00 0.13 0.70 0.52–0.87
    rCBVmax 0.82 0.63 2.77 0.73 0.54–0.91
    FA + rCBVmax 0.79 0.75 0.77 0.81 0.66–0.95
TP vs mixed
    CP 0.71 0.83 0.07 0.83 0.69–0.97
    FA 0.71 0.75 0.13 0.76 0.56–0.95
    CL 0.71 0.75 0.04 0.69 0.49–0.90
    rCBVmax 0.62 0.83 4.06 0.74 0.57–0.92
    FA + CL + rCBVmax 0.76 1.00 0.65 0.90 0.78–1.00
PsP vs mixed
    MDmin 0.50 0.88 0.98 0.62 0.34–0.89

Note:—MDmin indicates minimum MD.

a

The unit for MD is ×10−3mm2/s.