Skip to main content
. 2016 May;37(5):970–975. doi: 10.3174/ajnr.A4656

Acquisition parameters of MR imaging sequences

Segment Sequence Plane FOV (mm) Acquisition Matrix Thickness (mm) TR (ms) TE (ms) TI (ms) No. of Signals Acquired Acquisition Time (min:sec) Parallel Imaging
Cervical PSIR Sagittal 220 320 × 224 3 2400 9.4 400 2 4:45 GRAPPA 2
Cervical STIR Sagittal 300 448 × 336 3 400 51 200 1 5:46 GRAPPA 2
Cervical FSE PD Sagittal 220 320 × 288 3 2500 23 1 2:02 None
Cervical FSE T2 Sagittal 220 384 × 307 3 3500 106 2 3:35 None
Cervical GE T2 Transverse 180 256 × 218 3 740 17 2 4:25 GRAPPA 2
Thoracic PSIR Sagittal 330 384 × 269 3 2400 9.5 400 2 4:45 GRAPPA 2
Thoracic STIR Sagittal 330 448 × 336 3 4000 50 200 1 5:46 GRAPPA 2
Thoracic FSE PD Sagittal 330 320 × 288 3 2500 21 1 4:02 None
Thoracic FSE T2 Sagittal 330 448 × 336 3 4000 96 1 4:26 None
Thoracic FSE T2 Transverse 180 256 × 176 5 6780 107 2 4:46 None

Note:—GE indicates gradient-echo; PD, proton density; GRAPPA, generalized autocalibrating partially parallel acquisition.