Prevalence of imaging signs and concordance with low PCSFa

Overall Prevalence
Concordant Sign and PCSF
Discordant Sign and PCSF
Sign Absent, PCSF ≤6
Sign Present, PCSF >6
% No./Total % No./Total % No./Total % No./Total
Dural enhancement 83 77/93 39 36/93 5 5/93 56 52/93
Brain sagging 61 60/99 55 54/99 9 9/99 36 36/99
Venous distension sign 75 75/99 42 42/99 8 8/99 49 49/99
Leak on myelogram 55 54/99 55 54/99 12 12/99 33 33/99
a

Concordance is defined as the presence of the imaging sign when PCSF is low (≤6 cm H2O) or absence of the sign when PCSF is not low.