Skip to main content
. 2021 Mar 15;12:1672. doi: 10.1038/s41467-021-21819-8

Table 1.

Data and refinement statistics calculated for probe-only and pump–probe data.

Analysis approach Same resolution limits imposed Automatically determined high-resolution limits
Data set Single-pulse pump–probe Single-pulse (all) Single-pulse pump–probe Single-pulse (all)
# diffraction images used 3500 3500 5500 3500 3500 5500
Space group P212121 P212121 P212121 P212121 P212121 P212121
Cell dimensions (Å, °)

55.7 158.1 67.7

90.0 90.0 90.0

55.4 157.8 67.4

90.0 90.0 90.0

55.7 158.1 67.7

90.0 90.0 90.0

55.7 158.1 67.7

90.0 90.0 90.0

55.4 157.8 67.4

90.0 90.0 90.0

55.7 158.1 67.7

90.0 90.0 90.0

# indexed 3500 3500 5500 3500 3500 5500
Resolution (Å) 27.85–2.50 (2.57–2.50) 27.42–2.50 (2.57–2.50) 28.48–2.50 (2.57–2.50) 28.48–2.53 (2.60–2.53) 27.42–2.77 (2.77–2.84) 28.48–2.54 (2.61–2.54)
I/σ(I) 2.1 (1.0) 2.0 (0.5) 2.4 (1.2) 2.1 (1.0) 2.5 (1.0) 2.4 (1.2)
Rsplit (%) 48.3 (105.7) 40.1 (235.3) 40.0 (91.4) 48.1 (100.3) 36.9 (115.7) 39.7 (89.6)
CC1/2 0.705 (0.172) 0.857 (0.107) 0.8 (0.294) 0.702 (0.233) 0.851 (0.307) 0.798 (0.317)
CC* 0.909 (0.542) 0.961 (0.44) 0.943 (0.674) 0.908 (0.615) 0.959 (0.686) 0.942 (0.694)
Completeness (%) 99.9 (99.7) 99.8 (99.7) 100.0 (99.9) 99.9 (100.0) 99.8 (99.7) 100.0 (100.0)
Multiplicity 18.2 (12.4) 16.4 (11.0) 28.1 (19.1) 18.4 (12.3) 18.3 (11.8) 28.6 (18.9)
Wilson B (Å2) 47.4 59.0 48.3 48.2 61.2 49.2
Refinement
Unit cell parameters: a b c, α β γ (Å,°) 55.7 158.1 67.7, 90.0 90.0 90.0
Images used 3500 3500 5500
Resolution (Å) 28.48–2.53 27.42–2.77 28.48–2.54
No. reflections 19541 14810 19339
Rwork/Rfree 0.22757/0.28826 0.18841/0.27316 0.20701/0.27266
No. atoms
    Protein 4332 4332 4332
 Ligands

172 (4 haems)

8 (4 COs)

172 (4 haems)

8 (4 COs)

172 (4 haems)

8 (4 COs)

 Water 38 38 38
B-factors (Å2)
 Chain A (haem A) 42.1 (35.7) 52.4 (47.1) 41.3 (35.5)
 Chain B (haem B) 46.4 (41.6) 57.8 (53.2) 46.3 (42.4)
 Chain C (haem C) 50.3 (40.9) 59.9 (53.4) 49.5 (40.4)
 Chain D (haem D) 56.1 (45.5) 68.5 (57.4) 55.5 (45.2)
 Water 41.4 49.6 42.7
R.m.s deviations
 Bond lengths (Å) 0.007 0.008 0.007
 Bond angles (°) 1.490 1.608 1.549
Percentage of residues in Ramachandran plot region
 Preferred 95.4 93.8 94.6
 Allowed 4.1 5.5 4.7
 Disallowed 0.5 0.7 0.7
 PDB code 7AET 7AEV 7AEU

Values are given for either applying the same or automatically determined resolution limits, respectively, for the probe-only and pump/probe data. The first/fourth columns show the statistics of the probe data, the second/fifth for the pump/probe data using the same number of images and the third/six column the statistics of the single-pulse data, using all images available. All diffraction images that passed the filtering set were included in this analysis, irrespective of the probe pulse energy. For the automatic resolution determination, each data set was divided into 20 resolution bins, and I/σ(I) was calculated for each bin. The resolution of the bin where this value was still >1.0 was taken as the high-resolution limit.