Skip to main content
. 2021 Mar 9;62(3):12. doi: 10.1167/iovs.62.3.12

Table.

Relationship Between CNV Complexity and Choriocapillaris FDs

Highest Flow Flow Thickness No. of Flow Layers Flow Layers 1–2 Flow Layers 2–3 Flow Layers 1–3
Location FD Parameter Threshold Technique Average (SD) r P Value r P Value P Value z P Value z P Value z P Value
Outside Annulus FD Count Phansalkar 325 (247) −0.619* <0.001 −0.398* 0.032 0.019* −9.568* 0.016 −2.960 0.439 −12.528* 0.002
FD Count MinError(I) 237 (180) −0.643* <0.001 −0.394* 0.035 0.010* −11.000* 0.005 −2.000 0.601 −13.000* 0.002
FDD Phansalkar 0.41 (0.05) 0.433* 0.019 0.347 0.065 0.105
FDD MinError(I) 0.40 (0.17) 0.413* 0.026 0.443* 0.016 0.076
MFDS Phansalkar 92 (24) 0.462* 0.012 0.348 0.064 0.078
MFDS MinError(I) 134 (128) 0.451* 0.014 0.462* 0.012 0.043* 10.852* 0.006 −1.838 0.631 9.014* 0.029
Outside CNV FD Count Phansalkar 413 (242) −0.596* 0.001 −0.417* 0.025 0.023* −9.352* 0.018 −2.939 0.442 −12.292* 0.003
FD Count MinError(I) 306 (179) −0.607* <0.001 −0.403* 0.030 0.007* −11.830* 0.003 −1.101 0.774 −12.931* 0.002
FDD Phansalkar 0.42 (0.05) 0.436* 0.018 0.369* 0.049 0.076
FDD MinError(I) 0.41 (0.16) 0.456* 0.013 0.503* 0.005 0.028* 11.739* 0.003 −3.364 0.379 8.375* 0.043
MFDS Phansalkar 89 (21) 0.406* 0.029 0.312 0.100 0.135
MFDS MinError(I) 111 (59) 0.422* 0.023 0.473* 0.009 0.028* 11.739* 0.003 −3.364 0.379 8.375* 0.043
Annulus FD Count Phansalkar 88 (32) 0.276 0.147 0.016 0.936 0.361
FD Count MinError(I) 69 (32) 0.089 0.646 −0.014 0.943 0.819
FDD Phansalkar 0.45 (0.06) 0.214 0.265 0.381* 0.042 0.045* 10.784* 0.006 −6.242 0.103 4.542 0.272
FDD MinError(I) 0.44 (0.16) 0.397* 0.033 0.507* 0.005 0.011* 12.750* 0.001 −5.000 0.191 7.750 0.061
MFDS Phansalkar 86 (18) 0.183 0.342 0.335 0.076 0.034* 11.023* 0.005 −7.162 0.061 3.861 0.351
MFDS MinError(I) 105 (54) 0.360 0.055 0.471* 0.010 0.012* 12.750* 0.001 −4.889 0.201 7.861 0.057

Correlation between FD parameters and highest CNV flow or CNV flow thickness were performed with Spearman rank correlations reported with r and P values. Correlation between FD parameters and the categorical value of number of flow layers were performed with the Kruskal–Wallis H test (one-way ANOVA on ranks) with P value reported. If the Kruskal–Wallis was significant, post hoc Dunn tests were reported for individual comparisons between layers with pairwise z test statistics and P values. The MFDS is reported as diameter in microns.

*

P < 0.05.