Skip to main content
. 2021 Mar 3;10(5):1048. doi: 10.3390/jcm10051048

Table 5.

The diagnostic yield of studies on EUS-FNA.

Authors Year Number of Patients Sensitivity (%) Specificity (%) Accuracy (%) Adverse Events, n
Fritscher-Ravens et al. [74] 2004 44 89 100 91 None
Rösch et al. [75] 2004 50 43 100 70 N/A
DeWitt et al. [76] 2006 24 77 100 79 None
Mohamadnejad et al. [71] 2011 81 73 N/A N/A 1 (hemobilia)
Weilert et al. [77] 2014 51 94 100 94 None
Onda et al. [78] 2016 47 84 100 87 None

EUS-FNA, endoscopic ultrasound-guided fine-needle aspiration; N/A, not available.