Skip to main content
. Author manuscript; available in PMC: 2022 Mar 30.
Published in final edited form as: Mater Sci Eng A Struct Mater. 2021 Feb 13;809:140925. doi: 10.1016/j.msea.2021.140925

Table 1:

Comparison of CAD and experimental lattice volumes for each of the specimens. Note that an expansion value has been accounted for concerning our system’s slicing software’s tendency to over-build attices on the 200-300μm length scale.

Specimen CAD Lattice Volume (mm3) Experimental Lattice Volume (mm3) Percent Difference from CAD Model (%)
HCP 752 824 8.70%
BCC 477 479 0.38%
Checkered 579 619 6.43%
Row-Layered 648 648 −0.03%
Column Layered 605 605 0.07%
HCP Outer BCC Inner 512 497 −3.12%
HCP Inner BCC Outer 507 533 4.81%