Skip to main content
. 2010 Feb;31(2):251–256. doi: 10.3174/ajnr.A1796

Table 2:

Accuracy for patients who had surgerya

Surgical Pathology Reader A
Reader B
Averaged
Standard Neck CT Larynx Protocol Standard Neck CT Larynx Protocol Standard Neck CT Larynx Protocol
Accuracy (total), n = 17 0.65 (11) 0.71 (12) 0.35 (6) 0.35 (6) 0.50 0.53
Supraglottis, n = 7 0.57 (4) 0.57 (4) 0.71 (5) 0.14 (1) 0.64 0.36
Glottis, n = 9 0.67 (6) 0.89 (8) 0.00 (0) 0.44 (4) 0.34 0.67
a

The subset of patients who had surgery and thus had surgical pathology information was analyzed separately. As in Table 1, the accuracy is expressed as a total and individually for supraglottic cases and glottic cases.