Differences in diagnostic performance of C-CTA and R-CTA

Variables C-CTA R-CTA ORa P Values
Subject-based analysis
    Feeder detection accuracy (%)
        Observer 1 47 (7/15) 80 (12/15) .025b
        Observer 2 40 (6/15) 73 (11/15) .025b
    Time required for diagnosis (sec)
        Observer 1 97.1 ± 37.4 45.1 ± 23.6 .002b
        Observer 2 89.5 ± 60.0 45.6 ± 24.1 .020b
Intervertebral foramen–based analysis
    Sensitivity (%)c 44.4 (22.2–66.7) 72.2 (50.0–94.4) 3.26 (0.82–13.0) .095
    Specificity (%)c 98.1 (97.8–99.5) 99.5 (98.7–100) 3.55 (0.87–14.5) .077
    Accuracy (%)c 95.6 (93.8–97.2) 98.2 (96.9–99.2) 2.49 (1.04–6.00) .041b
a

ORs of R-CTA against C-CTA are shown.

b

Significant.

c

95% Confidence intervals are shown.