Skip to main content
. 2014 Mar;35(3):472–477. doi: 10.3174/ajnr.A3740

Table 2:

Performance of selected nontransformed (model A) and covariate transformed (model B) perfusion thresholds for tissue fate prediction in derivation and validation data bases

Perfusion Parameter Derivation Data Base
Validation Data Base
Sens. Spec. Acc. Sens. Spec. Acc.
CBF-GM-Rel
    A) Without any covariate 0.88 0.89 0.88 0.72 1 0.82
    B) With covariates 0.89 0.93 0.91 0.78 1 0.86
CBF-WM-Rel
    A) Without any covariate 0.86 0.84 0.85 0.76 0.95 0.82
    B) With covariates 0.90 0.80 0.86 0.79 0.91 0.83
Tmax-GM-Abs
    A) Without any covariate 0.80 0.92 0.84 0.70 0.93 0.78
    B) With covariates 0.84 0.96 0.88 0.69 0.97 0.79
Tmax-WM-Abs
    A) Without any covariate 0.76 0.85 0.79 0.70 0.88 0.76
    B) With covariates 0.80 0.80 0.80 0.64 0.94 0.76

Note:—Rel indicates relative to the contralateral side; Abs, absolute value; Sens, sensitivity; Spec, specificity; Acc, accuracy.