Summary of the essential imaging parameters for PICORE and FAIR ASL sequences

PICORE Q2TIPS FAIR-QUIPSS II
Matrix 64 × 64 64 × 64
No. of sections 20 24
Pixel size (mm2) 3.44 × 3.44 3.44 × 3.44
Section thickness (mm) 6 4
Gap (mm) 1 0
FOV 220 220
Parallel imaging (GRAPPA) 2 2
Phase, partial Fourier 7/8 6/8
Section order Ascending Ascending
Section orientation ACPC aligned ACPC aligned
Fat saturation Yes Yes
Coil-combination algo Sum of squares Sum of squares
Bandwidth 2604 Hz/Px 2368 Hz/Px
Echo-spacing 0.47 0.49
Saturation slab Parallel feet, gap = 25.6 mm, thickness = 110 mm Parallel feet/head gap = 10 mm, thickness = 100 mm
TE (ms) 21 12
TR (ms) 5000 4000
TI 1 (ms) 700 600
TI 2 (ms) 1800 1600
Saturation stop time (ms) 1600
Flow limit (cm/s) 5 100
No. of images 71 105
Total acquisition time 6 Minutes 12 seconds 7 Minutes 6 seconds
Mo reference image No Yes

Note:—ACPC indicates anterior/posterior commissure; algo, algorithm; Q2TIPS, quantitative imaging of perfusion with a single subtraction with thin-section TI1 periodic saturation; QUIPSS II, quantitative imaging of perfusion using a single subtraction II; Mo, steady-state magnetization; GRAPPA, generalized autocalibrating partially parallel acquisitions.