Skip to main content
. 2012 Aug;33(7):1267–1273. doi: 10.3174/ajnr.A2970

Table 4:

Intraobserver and interobserver variability (n = 30 carotid arteries) of the semiautomatic segmentation method

Intraobserver
Interobserver
Mean ± SD Diff Obs ICC CoV (%) Mean ± SD Diff Obs ICC CoV (%)
Vessel volume (mm3) 2606 ± 830 50 ± 244 0.96 9.4 2743 ± 848 323 ± 407 0.84 14.9
Lumen volume (mm3) 1527 ± 535 −5 ± 152 0.96 10.0 1630 ± 567 201 ± 266 0.85 16.3
Plaque volume (mm3) 1079 ± 350 55 ± 120 0.93 11.1 1112 ± 334 123 ± 164 0.84 14.7
Fibrous volume (mm3) 649 ± 178 33 ± 64 0.92 9.9 675 ± 185 86 ± 115 0.76 17.0
Lipid volume (mm3) 316 ± 114 19 ± 60 0.86 19.0 326 ± 110 39 ± 70 0.78 21.5
Calcium volume (mm3) 114 ± 120 3 ± 7 1.00 6.5 112 ± 115 2 ± 13 0.99 12.0
Fibrous proportion (%) 61 ± 8 0.5 ± 2.8 0.94 4.6 62 ± 8 0.8 ± 2.7 0.94 4.5
Lipid proportion (%) 29 ± 4 0.1 ± 3.0 0.78 10.4 29 ± 5 0.4 ± 3.0 0.80 10.2
Calcium proportion (%) 9 ± 8 −0.6 ± 1.1 0.99 11.4 9 ± 8 1.2 ± 2.0 0.96 22.0

Note:—Diff Obs indicates difference between observers.