Skip to main content
. 2011 May;32(5):938–946. doi: 10.3174/ajnr.A2386

Table 3:

Sensitivity, specificity, PPV, and NPV of MRV (TOF and TRICKS) and Doppler sonography relative to catheter venography (criterion standard) for detection of IJV anomaliesa

Measure/Side Sensitivity (%) Specificity (%) PPV (%) NPV (%)
TOF
    Right 99 (44–100) 33 (3–51) 45 (12–65) 99 (21–100)
    Left 99 (21–100) 45 (12–065) 33 (3–51) 99 (44–100)
    Both 99 (51–100) 33 (10–49) 33 (10–49) 99 (51–100)
TRICKS
    Right 99 (44–100) 44 (8–64) 49 (14–69) 99 (34–100)
    Left 99 (21–100) 45 (12–65) 33 (3–51) 99 (44–100)
    Both 99 (51–100) 39 (14–56) 35 (11–52) 99 (57–100)
DS
    Right 79 (21–94) 100 (65–100) 99 (34–100) 90 (53–98)
    Left 99 (21–100) 100 (70–100) 99 (21–100) 100 (70–100)
    Both 82 (30–95) 100 (81–100) 99 (44–100) 95 (73–99)
a

95% confidence intervals are shown in parentheses for all values.