Skip to main content
. 2021 Mar 17;44(2):387–394. doi: 10.1007/s13246-021-00988-2

Table 1.

Test results of the SGD and NB classifiers for the five operators with images obtained without the contrast medium

AUC CA F1 Precision Sensitivity
SVM / SGD SVM / SGD SVM / SGD SVM / SGD SVM / SGD
Operator 1 0.95/0.91 0.90/0.91 0.89/0.91 0.90/0.91 0.90/0.91
Operator 2 0.98/0.85 0.94/0.89 0.94/0.89 0.94/0.89 0.93/0.89
Operator 3 0.87/0.83 0.90/0.91 0.89/0.91 0.91/0.91 0.90/0.91
Operator 4 0.98/0.93 0.91/0.93 0.91/0.93 0.93/0.93 0.91/0.93
Operator 5 0.96/0.80 0.83/0.84 0.79/0.83 0.86/0.85 0.83/0.91
Mean + Standard deviation 0.95 ± 0.05/0.88 ± 0.05 0.90 ± 0.04/0.90 ± 0.04 0.88 ± 0.06/0.90 ± 0.04 0.91 ± 0.03/0.91 ± 0.03 0.89 ± 0.03/0.84 ± 0.04