Table 3.

Estimate of uncertainty in 1 s (2 s for O3) measurements due to random (σprecision) and systematic (σbias) uncertainties during the 14 stationary collocation periods.

Parameter σprecision Bias1 Bias2 Bias3 σbias σtotal

O3 (ppbv) 2.3 1.8 −2.5 1.5 2.8 3.6
NO2 (ppbv) 2.3 −0.5 −0.9 1.4 1.5 2.7
NO (ppbv) 5.9 0.2 −0.5 0.0 2.0 6.2
BC (μg∙m−3) 0.52 −0.11 0.11 0.21 0.56
1BC* (μg∙m−3) 0.42 0.05 −0.05 0.08 0.43
PN0.3–0.5 (L −1) 1300 925 −752 −87 991 1635
PN0.5–1.0 (L−1) 251 14 3 −24 31 253
PN1.0–2.0 (L−1) 93 9 1 −6 11 94
PN2.0–5.0 (L−1) 64 13 −7 −7 12 65
1

BC* is black carbon after correction for the systematic bias in Car 2 (Section 4.4).