Table 2.
Platelet rich fibrin matrices (L-PRF, A-PRF, and A-PRF +) prepared with the centrifuge process for PRF, Nice, France, (DUO)] and the Intra-Spin centrifuge [Intra-Lock, Biohorizons, Birmingham, Alabama, USA, (IL)]7.
| Device | Tube | Setting | |||||
|---|---|---|---|---|---|---|---|
| RCFclot (g) | RCFmax (g) | Rotor angulation (°) | rpm | Time (min) | |||
| L-PRF-IL | Intra-Lock, USA | Plastic-coated | 408 | 653 | 33 | 27,000 | 12 |
| L-PRF-DUO | Process for PRF, France | Glass | 408 | 653 | 40 | 1825 | 12 |
| A-PRF-IL | Intra-Lock, USA | Plastic-coated | 193 | 276 | 33 | 2200 | 14 |
| A-PRF-DUO | Process for PRF, France | Glass | 193 | 276 | 40 | 1500 | 14 |
| A-PRF + -IL | Intra-Lock, , USA | Plastic-coated | 145 | 208 | 33 | 1900 | 8 |
| A-PRF + -DUO | Process for PRF, France | Glass | 145 | 208 | 40 | 1300 | 8 |