Skip to main content
. Author manuscript; available in PMC: 2021 Mar 22.
Published in final edited form as: IEEE Trans Med Imaging. 2018 Jun 25;37(12):2695–2703. doi: 10.1109/TMI.2018.2849959

TABLE II.

Model Performance for Classification of Cores in the Test Data for Different MR Suspicious Levels. N Indicates Number of Cores in Each Group

MR suspicious levels Moderate MR suspicious level (N = 115)
High MR suspicious level (N = 20)
Specificity Sensitivity Accuracy AUC Specificity Sensitivity Accuracy AUC
LSTM 0.98 0.78 0.95 0.97 0.86 0.92 0.90 0.97
GRU 0.95 0.70 0.89 0.91 0.80 1.00 0.90 0.92
Vanilla RNN 0.82 0.70 0.82 0.73 0.85 0.67 0.70 0.68
Spectral [17] 0.70 0.78 0.80 0.80 0.83 0.90 0.85 0.95