Skip to main content
. 2020 Nov 11;53(4):1268–1279. doi: 10.1002/jmri.27431

TABLE 5.

Interobserver Reproducibility Results of the Clinical Cohort

Bland–Altman Pearson correlation
Study Mean Diff LoA COV [%] r P ICC
Volume [cm3 = mL]
IE–O1 −1.0 5.9 12 0.98 <0.01 0.99
IE‐O2 1.2 14.9 32 0.89 <0.01 0.94
IE‐O3 2.2 14.2 30 0.89 <0.01 0.94
Surface area [cm2]
IE–O1 −3.3 11.1 16 0.95 <0.01 0.96
IE‐O2 −0.6 18.9 29 0.83 <0.01 0.90
IE‐O3 2.7 14.2 21 0.89 <0.01 0.93
Centerline length [mm]
IE–O1 −0.6 8.8 10 0.94 <0.01 0.97
IE‐O2 2.0 13.1 16 0.87 <0.01 0.91
IE‐O3 2.6 11.9 15 0.88 <0.01 0.92
Maximal diameter [mm]
IE–O1 −0.2 2.5 4 0.98 <0.01 0.99
IE‐O2 0.1 5.1 8 0.93 <0.01 0.96
IE‐O3 0.3 5.4 8 0.93 <0.01 0.96
Curvature radius [mm]
IE–O1 −0.9 31.1 25 0.95 <0.01 0.97
IE‐O2 4.3 48.1 40 0.85 <0.01 0.90
IE‐O3 5.2 53.6 44 0.84 <0.01 0.89

Results are presented over all subjects, cardiac phases, and anatomical segments (n = 150). Mean Diff = mean difference, LoA = limits of agreement – ±1.96. *Standard deviation mean difference.