Skip to main content
. 2016 Sep;37(9):1706–1712. doi: 10.3174/ajnr.A4792

Table 2:

ADC skewness threshold obtained from ROC curve analysis to predict local failure

Parameter ADC Skewness
Threshold ≤0.55
P value .0001
Area under the ROC curve 0.68
True-positive 21
False-positive 49
True-negative 82
False-negative 6
Sensitivity 78%
Specificity 63%
Accuracy 65%
Positive predictive value 30%
Negative predictive value 93%