Skip to main content
. 2021 Feb 6;48(3):1226–1238. doi: 10.1002/mp.14684

Table II.

Features selected for different volume ranges.

Feature name Selected by which volume range
Gray_level_non_uniformity (GLCM, 2Davg) All volume ranges
Gray_level_non_uniformity (GLCM, 2Dmrg) All volume ranges >= 3.2 mL
long_runs_emphasis (GLRLM, 2Davg) All volume ranges >= 11.4 mL
Run_percentage (GLRLM 2DWmrg) All volume ranges >= 33.4 mL
Run_length_variance (GLRLM 2Dvmrg) All volume ranges >= 33.4 mL
Gray_level_non_uniformity (GLRLM, 3Davg) All volume ranges >= 33.4 mL
Gray_level_non_uniformity (GLDZM 2Davg) All volume ranges >=33.4 mL
Zone_percentage (GLDZM 2Davg) All volume ranges >= 33.4 mL
Gray_level_non_uniformity (GLDZM 3D) All volume ranges >= 33.4 mL
Zone_distance_non_uniformity (GLDZM 2Davg) All volume ranges >= 45 mL
Zone_distance_non_uniformity (GLDZM 2Dmrg) All volume ranges >= 45 mL
coarseness (NGLDM 2Dmrg) All volume ranges >= 103.9 mL
small_distance_emphasis (GLDZM 2Davg) All volume ranges >= 103.9 mL
Dependence_count_non_uniformity (NGTDM 2Dmrg) ALL volume ranges >= 103.9 mL
Dependence_count_entropy (NGTDM 2Davg) All volume ranges >= 103.9 mL