Skip to main content
. 2021 Mar 23;51(5):3104–3120. doi: 10.1007/s10489-021-02199-4

Table 7.

Test accuracy of the ResNet50 model without data balance on the COVID-19 CXR dataset

X-ray Support Accu- Jaccard Precision Recall f1- Specifi-
type racy Index score city
COVID-19 38 0.97 0.90 0.93 0.97 0.95 0.99
Viral- 273 0.84 0.83 0.99 0.84 0.91 0.99
pneumonia
Normal 270 0.98 0.86 0.87 0.99 0.92 0.87
Sum 581
Average 0.91 0.85 0.92 0.92 0.92 0.96