Table 4.

Lung function parameters.

Controls n = 125 GLILD n = 47 uILD n = 26 p value p value p value
Median (IQR) Median (IQR) Median (IQR) (GLILD vs. ctrls) (uILD vs. GLILD) (uILD vs. ctrls)
FEV1 (% of predicted) 102 (89–111) 88 (72–105) 103 (89–110) 0.02 0.03 0.94
0.006 0.15 0.35
FVC (% of predicted) 104 (92–116) 88 (72–103) 104 (93–113) <0.001 0.01 0.72
<0.001 0.01 0.40
TLC (% of predicted) 102 (94–108) 87 (75–102) 93 (87–104) <0.001 0.32 0.03
0.001 0.29 0.05
DLCO (% of predicted) 83 (75–97) 61 (52–80) 73 (65–86) <0.001 0.008 0.02
<0.001 0.02 0.07

For each cell: Upper p-value from Wilcoxon-Mann-Whitney test. Lower p value from linear regression models adjusted for disease duration (difference between age at enrolment and age at CVID onset).