Skip to main content
. Author manuscript; available in PMC: 2021 Sep 1.
Published in final edited form as: Toxicol Sci. 2020 Sep 1;177(1):41–59. doi: 10.1093/toxsci/kfaa102

Table 1.

Predictive accuracies using biomarker thresholds.

Training Set Test Set Unit TP TN FP FN Sensitivity Specificity PPV NPV Balanced accuracy
TG-Training TG-Test Chemical 9 27 2 0 1.000 0.931 0.818 1.000 0.966
TG-All DM-All Chemical 33 23 20 1 0.971 0.535 0.623 0.958 0.753
DM-All TG-All Chemical 17 55 2 1 0.944 0.965 0.895 0.982 0.955
DM-All TG-4d Chemical 17 57 0 1 0.944 1.000 1.000 0.983 0.972
DM-All TG-8d Chemical 17 57 0 1 0.944 1.000 1.000 0.983 0.972
DM-All TG-15d Chemical 17 56 1 1 0.944 0.982 0.944 0.982 0.963
DM-All TG-29d Chemical 17 55 2 1 0.944 0.965 0.895 0.982 0.955

DM, DrugMatrix; TG, TG-GATES; TP, true positive; TN, true negative; FP, false positive; FN, false negative; PPV, positive predictive value; NPV, negative predictive value.