Skip to main content
. 2021 Mar 15;11(3):518. doi: 10.3390/diagnostics11030518

Table 3.

The quantitative results of the Faster R-CNN. All 194 PC BS images were shuffled 10 times. One shuffle means one cross-validation.

Shuffle Number Lesion-Based
Sensitivity Precision
Patient-Based
Sensitivity Specificity
1 0.77 0.66 1.00 0.90
2 0.67 0.59 1.00 0.70
3 0.75 0.68 1.00 0.60
4 0.65 0.50 0.86 0.36
5 0.68 0.59 0.88 0.64
6 0.74 0.67 0.88 1.00
7 0.56 0.78 1.00 0.73
8 0.70 0.54 0.88 0.82
9 0.72 0.74 0.89 0.70
10 0.48 0.77 0.75 0.82
Average 0.67 ± 0.09 0.65 ± 0.10 0.91 ± 0.08 0.73 ± 0.18