Materials τrise (ms) τfall (ms) R (A/W) Detectivity (Jones) Reference
CH3NH3PbI3 Nanowire 0.1 0.1 4.95
(1 nW/cm2@530 nm)
2 × 1013 [15]
2D Perovskite 20 40 12
(15.0 mW/cm2@532 nm)
Not given [40]
Graphene/Perovskite 87 540 180
(1 μW@780 nm)
109 [8]
Graphene/Perovskite ~120 ~750 6.0 × 105 (1.05 nW@405 nm) Not given [20]
CH3NH3PbI3 Nanowire/Graphene 5.5 × 104 7.5 × 104 2.6 × 106 (3.3 pW@633 nm) Not given [21]
CH3NH3PbIxCl3-x/Graphene Nanowalls 50 290 2016.7
(40 μW@635 nm)
7.2 × 1010 This work