Skip to main content
. 2021 Mar 16;21(6):2083. doi: 10.3390/s21062083

Table 2.

Summary of the agreement statistics, quantified as the Concordance Correlation Coefficient (CCC), bias correction error and Bland-Altman Limits of Agreement (LOA) interval. The best unbiased estimates are given with the 95% confidence intervals given in parentheses. The units of LOA intervals are the same as the body composition index. CCC and bias correction are dimensionless.

Concordance Correlation Bias Correction Error Limits of Agreement
SMRA
All 0.92 (0.91–0.94) 0.98 −0.99 (−9.3–7.3) HU
Sub: hands 0.89 (0.85–0.92) 0.96 −1.0 (−10–8.2) HU
Sub: no hands 0.95 (0.93–0.96) 0.99 −0.97 (−8.5–6.6) HU
SMI
All 0.71 (0.64–0.76) 0.93 −4.0 (−21–13) kg·m−2
All (interobs.) 0.88 (0.86–0.91) 0.97 −2.7 (−12–6.3) kg·m−2
Sub: hands 0.58 (0.48–0.67) 0.74 −9.4 (−25–6.2) kg·m−2
Sub: no hands 0.83 (0.77–0.88) 0.99 −0.69 (−28–29) kg·m−2
VATI
All 0.99 (0.98–0.99) 1.00 0.98 (−9.7–12) kg·m−2
Sub: hands 0.98 (0.97–0.98) 1.00 0.87 (−12–14) kg·m−2
Sub: no hands 0.99 (0.99–0.99) 1.00 1.1 (−7.0–9.1) kg·m−2
SATI
All 0.99 (0.98–0.99) 1.00 0.29 (−9.8–10) kg·m−2
Sub: hands 0.99 (0.98–0.99) 1.00 0.00 (−9.2–9.2) kg·m−2
Sub: no hands 0.99 (0.98–0.99) 1.00 0.52 (−10–11) kg·m−2