Skip to main content
. 2021 Mar 17;13(6):923. doi: 10.3390/polym13060923

Table 4.

Composition, experimental vs. predicted value with percentage error of optimized PLM-loaded glycerosome formulation.

Variables Optimum Composition Response Observed Value of Response Predicted Value of Response Percentage Error
X1 15 mg Y1 119.20 ± 15.67 110.53 8.18
X2 4 mg Y2 76.42 ± 9.98 74.09 3.14
X3 26.8% w/v Y3 79.43 ± 12.43 76.12 4.34

Predicted error (%) = (observed value − predicted value)/predicted value × 100%; X1, Phospholipid (mg); X2, Cholesterol (% v/v); X3, Glycerol, Y1, Vesicles size (nm); Y2, Entrapment efficiency; Y3, Drug permeation/Flux (μg/cm2/h).