Table 1 –
Total tissue stretches ( and ) and anisotropy index of each region for the MVAL and TVAL leaflets (c.f. Fig. 2 & Fig. 3). Reported values are for equibiaxial testing protocol (Tcirc,max:Trad,max = 1:1). All values are reported as mean ± SEM.
Valve | Region | Anisotropy Index | ||
---|---|---|---|---|
MVAL | A (n=13) | 1.301±0.043 | 1.259±0.038 | 0.977 ± 0.034 |
B (n=13) | 1.189±0.021 | 1.280±0.035 | 1.076 ± 0.018 | |
C (n=13) | 1.250±0.030 | 1.261±0.030 | 1.010 ± 0.015 | |
D (n=12) | 1.239±0.029 | 1.281±0.032 | 1.036 ± 0.018 | |
E (n=13) | 1.194±0.021 | 1.317±0.043 | 1.103 ± 0.030 | |
F (n=13) | 1.224±0.037 | 1.253±0.034 | 1.030 ± 0.030 | |
TVAL | A (n=13) | 1.380±0.065 | 1.400±0.035 | 1.019 ± 0.027 |
B (n=13) | 1.322±0.033 | 1.444±0.076 | 1.086 ± 0.039 | |
C (n=13) | 1.371±0.054 | 1.362±0.060 | 0.993 ± 0.021 | |
D (n=12) | 1.358±0.049 | 1.428±0.080 | 1.054 ± 0.051 | |
E (n=13) | 1.285±0.035 | 1.394±0.072 | 1.083 ± 0.043 | |
F (n=10) | 1.268±0.033 | 1.288±0.053 | 1.013 ± 0.020 |
Variation in the sample size (n) was due to tests in which tissue data was not successfully completely. For example: tissue tearing, testing failure, or dissection in which edge regions were not sufficiently large for biaxial mechanical testing.