Table 1 –

Total tissue stretches (λcirc0peak and λrad0peak) and anisotropy index of each region for the MVAL and TVAL leaflets (c.f. Fig. 2 & Fig. 3). Reported values are for equibiaxial testing protocol (Tcirc,max:Trad,max = 1:1). All values are reported as mean ± SEM.

Valve Region λcirc0peak λrad0peak Anisotropy Index
MVAL A (n=13) 1.301±0.043 1.259±0.038 0.977 ± 0.034
B (n=13) 1.189±0.021 1.280±0.035 1.076 ± 0.018
C (n=13) 1.250±0.030 1.261±0.030 1.010 ± 0.015
D (n=12) 1.239±0.029 1.281±0.032 1.036 ± 0.018
E (n=13) 1.194±0.021 1.317±0.043 1.103 ± 0.030
F (n=13) 1.224±0.037 1.253±0.034 1.030 ± 0.030
TVAL A (n=13) 1.380±0.065 1.400±0.035 1.019 ± 0.027
B (n=13) 1.322±0.033 1.444±0.076 1.086 ± 0.039
C (n=13) 1.371±0.054 1.362±0.060 0.993 ± 0.021
D (n=12) 1.358±0.049 1.428±0.080 1.054 ± 0.051
E (n=13) 1.285±0.035 1.394±0.072 1.083 ± 0.043
F (n=10) 1.268±0.033 1.288±0.053 1.013 ± 0.020

Variation in the sample size (n) was due to tests in which tissue data was not successfully completely. For example: tissue tearing, testing failure, or dissection in which edge regions were not sufficiently large for biaxial mechanical testing.